Click here to see the miniiSED® in action!
STAT results in only 15 seconds
Fully automated from primary EDTA tubes
100µL sample volume
No exposure to patient sample
Ideal compact size
High correlation to Westergren method
Easily interfaces to LIS
This compact fully-automated ESR analyzer utilizes photometric reading to quantify the Rouleaux formation, which is the earliest and most critical phase of sedimentation. miniiSED’s micro-flow cell captures the critical kinetics of RBC in highly controlled testing environment to produce ESR results in 15 seconds. The analyzers results are unaffected by the variables commonly associated with traditional ESR testing methods. Some of these variables include hematocrit, MCV and temperature.
The miniiSED® is the ideal ESR analyzer for emergency rooms, POLs, and small hospital laboratories.
Simply insert the primary EDTA sample tube in the sample entry port and walk away. This ESR analyzer will have results ready for you in 15 seconds instead of 15-60 minutes as when using traditional methods of ESR testing. The miniiSED® has a maximum throughput of 180 tests per hour.
No more graduated pipettes, special cuvettes, duplicate sample tubes, or sample transfer disposables! No longer generating contaminated waste, miniiSED® offers a decreased cost of ESR testing. In addition using closed-container sampling technology there is no staff exposure to patient sample.
The miniiSED® requires a sample volume of only 100 microliters of whole blood! There is no need to waste time drawing two EDTA tubes or a designated disposable tube. The small sample volume makes the miniiSED® the perfect ESR analyzer for pediatric and geriatric patients. Compatible with BD Microtainer® MAP Microtubes.
The miniiSED® saves you space on the lab bench or in the office. In fact the analyzer takes up about as much room as your office phone.
The miniiSED’s internal barcode reader assures all samples are correctly identified and tracked. The analyzer easily interfaces to LIS systems.
Principle of Measure: | Photometrical rheoscope |
Analytical Range | 1-130 mm/hr |
Sample Requirements: | 100µL whole blood (500µL dead volume) |
Tube Requirements: | 13 x 75 mm, test tube in EDTA anti-coagulant, capped |
Quality Control: | Barcoded Seditrol® QC |
Barcode Reader: | Internal |
Interface Specifications: | RJ-45 Ethernet for LIS connection |
Weight: | 4.445 kgs / 9.8 lbs |
Dimensions (H x W x D): | 24 x 18 x 26 (cm) /9.5 x 7.1 x 10.4 (in) |
Voltage: | 100-240VAC |
Frequency Range: | 50-60 Hz |
Power: | 60W |
112-01017 | miniiSED® ESR Analyzer |
112-00250 | Test card, 250 test credits |
DSC01 | Seditrol®, Lvl 1 & Lvl 2 (1 each) |
112-12-003 | miniiWASH (4/pk) |
112-12-004 | miniiWASTE (4/pk) |